Talk:Magnetic Resonance Imaging: Difference between revisions

From Embryology
Line 30: Line 30:
PMID: 20090188
PMID: 20090188
http://www.ncbi.nlm.nih.gov/pubmed/20090188
http://www.ncbi.nlm.nih.gov/pubmed/20090188
===Dealing with pregnancy in radiology: a thin line between science, social and regulatory aspects===
JBR-BTR. 2009 Nov-Dec;92(6):271-9.
Buls N, Covens P, Nieboer K, Van Schuerbeek P, Devacht P, Eloot L, de Mey J.
Dienst Radiologie and Dienst Fysische controle, UZ Brussel, Brussels, Belgium.
Abstract
The participation of pregnant women in radiology can be an emotional experience. The word "radiation" understandably invokes fear and uncertainty. Irradiation of a foetus should be avoided whenever possible. However, radiological examinations of pregnant women are often justified and unintended exposures do occur. Also pregnant radiology staff may remain working in the department. Lack of knowledge about the effects of both ionising (X-rays) and non-ionising (MRI) radiation is responsible for anxiety of patients and workers. If foetal exposures occur, they must be quantitatively evaluated and the risk put into perspective. This paper is intended to inform radiology managers, radiologists, technologists and referring clinicians in their management with pregnant patients and co-workers. The paper describes conceptus doses for both patient and worker that are associated with radiology practice, reviews the risks and effects of in utero irradiation, and discusses current national policies, international guidelines and practical aspects.
PMID: 20166494
http://www.ncbi.nlm.nih.gov/pubmed/20166494


===World-first at Charité: Birth in "open" MRI===
===World-first at Charité: Birth in "open" MRI===

Revision as of 15:45, 14 December 2010

About Discussion Pages  
Mark Hill.jpg
On this website the Discussion Tab or "talk pages" for a topic has been used for several purposes:
  1. References - recent and historic that relates to the topic
  2. Additional topic information - currently prepared in draft format
  3. Links - to related webpages
  4. Topic page - an edit history as used on other Wiki sites
  5. Lecture/Practical - student feedback
  6. Student Projects - online project discussions.
Links: Pubmed Most Recent | Reference Tutorial | Journal Searches

Glossary Links

Glossary: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | Numbers | Symbols | Term Link

Cite this page: Hill, M.A. (2026, November 19) Embryology Magnetic Resonance Imaging. Retrieved from https://embryology.med.unsw.edu.au/embryology/index.php/Talk:Magnetic_Resonance_Imaging

2010

Temperature elevation in the fetus from electromagnetic exposure during magnetic resonance imaging

Phys Med Biol. 2010 Apr 21;55(8):2411-26. Epub 2010 Apr 1.

Kikuchi S, Saito K, Takahashi M, Ito K.

Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan. kikuchi@graduate.chiba-u.jp Abstract This study computationally assessed the temperature elevations due to electromagnetic wave energy deposition during magnetic resonance imaging in non-pregnant and pregnant woman models. We used a thermal model with thermoregulatory response of the human body for our calculations. We also considered the effect of blood temperature variation on body core temperature. In a thermal equilibrium state, the temperature elevations in the intrinsic tissues of the woman and fetal tissues were 0.85 and 0.61 degrees C, respectively, at a whole-body averaged specific absorption rate of 2.0 W kg(-1), which is the restriction value of the International Electrotechnical Commission for the normal operating mode. As predicted, these values are below the temperature elevation of 1.5 degrees C that is expected to be teratogenic. However, these values exceeded the recommended temperature elevation limit of 0.5 degrees C by the International Commission on Non-Ionizing Radiation Protection. We also assessed the irradiation time required for a temperature elevation of 0.5 degrees C at the aforementioned specific absorption rate. As a result, the calculated irradiation time was 40 min.

PMID: 20360633 http://www.ncbi.nlm.nih.gov/pubmed/20360633

http://iopscience.iop.org/0031-9155/55/8/018


Numerical study of RF exposure and the resulting temperature rise in the foetus during a magnetic resonance procedure

Phys Med Biol. 2010 Feb 21;55(4):913-30. Epub 2010 Jan 20.

Hand JW, Li Y, Hajnal JV.

Imaging Sciences Department, Imperial College London, London W12 0NN, UK. j.hand@imperial.ac.uk Abstract Numerical simulations of specific absorption rate (SAR) and temperature changes in a 26-week pregnant woman model within typical birdcage body coils as used in 1.5 T and 3 T MRI scanners are described. Spatial distributions of SAR and the resulting spatial and temporal changes in temperature are determined using a finite difference time domain method and a finite difference bio-heat transfer solver that accounts for discrete vessels. Heat transfer from foetus to placenta via the umbilical vein and arteries as well as that across the foetal skin/amniotic fluid/uterine wall boundaries is modelled. Results suggest that for procedures compliant with IEC normal mode conditions (maternal whole-body averaged SAR(MWB) < or = 2 W kg(-1) (continuous or time-averaged over 6 min)), whole foetal SAR, local foetal SAR(10 g) and average foetal temperature are within international safety limits. For continuous RF exposure at SAR(MWB) = 2 W kg(-1) over periods of 7.5 min or longer, a maximum local foetal temperature >38 degrees C may occur. However, assessment of the risk posed by such maximum temperatures predicted in a static model is difficult because of frequent foetal movement. Results also confirm that when SAR(MWB) = 2 W kg(-1), some local SAR(10g) values in the mother's trunk and extremities exceed recommended limits.

PMID: 20090188 http://www.ncbi.nlm.nih.gov/pubmed/20090188

Dealing with pregnancy in radiology: a thin line between science, social and regulatory aspects

JBR-BTR. 2009 Nov-Dec;92(6):271-9.

Buls N, Covens P, Nieboer K, Van Schuerbeek P, Devacht P, Eloot L, de Mey J.

Dienst Radiologie and Dienst Fysische controle, UZ Brussel, Brussels, Belgium. Abstract The participation of pregnant women in radiology can be an emotional experience. The word "radiation" understandably invokes fear and uncertainty. Irradiation of a foetus should be avoided whenever possible. However, radiological examinations of pregnant women are often justified and unintended exposures do occur. Also pregnant radiology staff may remain working in the department. Lack of knowledge about the effects of both ionising (X-rays) and non-ionising (MRI) radiation is responsible for anxiety of patients and workers. If foetal exposures occur, they must be quantitatively evaluated and the risk put into perspective. This paper is intended to inform radiology managers, radiologists, technologists and referring clinicians in their management with pregnant patients and co-workers. The paper describes conceptus doses for both patient and worker that are associated with radiology practice, reviews the risks and effects of in utero irradiation, and discusses current national policies, international guidelines and practical aspects.

PMID: 20166494 http://www.ncbi.nlm.nih.gov/pubmed/20166494

World-first at Charité: Birth in "open" MRI

Developmental atlas of the early first trimester human embryo

http://onlinelibrary.wiley.com/doi/10.1002/dvdy.22316/full


2004

MR imaging of fetal abnormalities

Tamsel S, Ozbek SS, Sener RN, Oztekin O, Demirpolat G. Comput Med Imaging Graph. 2004 Apr;28(3):141-9. PMID: 15081497

2000

Ultrafast MR imaging of the fetus

Kubik-Huch RA, Huisman TA, Wisser J, Gottstein-Aalame N, Debatin JF, Seifert B, Ladd ME, Stallmach T, Marincek B. AJR Am J Roentgenol. 2000 Jun;174(6):1599-606. PMID: 10845491

Mouse Brain Atlas MRI Database

Contacted Dr Cecilia Lo (cel36@pitt.edu) 16 August, 14 December 2010. Chien-fu Chang (chc160@pitt.edu) applications developer.

Registered 14 December 2010 see email for login information.