===Fetal MRI: An approach to practice: A review===
J Adv Res. 2014 Sep;5(5):507-23. doi: 10.1016/j.jare.2013.06.001. Epub 2013 Jun 11.
Saleem SN.
Abstract
MRI has been increasingly used for detailed visualization of the fetus in utero as well as pregnancy structures. Yet, the familiarity of radiologists and clinicians with fetal MRI is still limited. This article provides a practical approach to fetal MR imaging. Fetal MRI is an interactive scanning of the moving fetus owed to the use of fast sequences. Single-shot fast spin-echo (SSFSE) T2-weighted imaging is a standard sequence. T1-weighted sequences are primarily used to demonstrate fat, calcification and hemorrhage. Balanced steady-state free-precession (SSFP), are beneficial in demonstrating fetal structures as the heart and vessels. Diffusion weighted imaging (DWI), MR spectroscopy (MRS), and diffusion tensor imaging (DTI) have potential applications in fetal imaging. Knowing the developing fetal MR anatomy is essential to detect abnormalities. MR evaluation of the developing fetal brain should include recognition of the multilayered-appearance of the cerebral parenchyma, knowledge of the timing of sulci appearance, myelination and changes in ventricular size. With advanced gestation, fetal organs as lungs and kidneys show significant changes in volume and T2-signal. Through a systematic approach, the normal anatomy of the developing fetus is shown to contrast with a wide spectrum of fetal disorders. The abnormalities displayed are graded in severity from simple common lesions to more complex rare cases. Complete fetal MRI is fulfilled by careful evaluation of the placenta, umbilical cord and amniotic cavity. Accurate interpretation of fetal MRI can provide valuable information that helps prenatal counseling, facilitate management decisions, guide therapy, and support research studies.
KEYWORDS:
Anomalies; Fetal; MRI; Prenatal
PMID 25685519


ref name=PMID25685519
ref name=PMID25685519
Line 10: Line 23:
<pubmed>25685519</pubmed>| [http://www.sciencedirect.com/science/article/pii/S2090123213000805 J Adv Res.]
<pubmed>25685519</pubmed>| [http://www.sciencedirect.com/science/article/pii/S2090123213000805 J Adv Res.]


Sahar Saleem
{{Sahar Saleem}}





Revision as of 09:46, 1 March 2015

About Discussion Pages  
Mark Hill.jpg
On this website the Discussion Tab or "talk pages" for a topic has been used for several purposes:
  1. References - recent and historic that relates to the topic
  2. Additional topic information - currently prepared in draft format
  3. Links - to related webpages
  4. Topic page - an edit history as used on other Wiki sites
  5. Lecture/Practical - student feedback
  6. Student Projects - online project discussions.
Links: Pubmed Most Recent | Reference Tutorial | Journal Searches

Glossary Links

Glossary: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | Numbers | Symbols | Term Link

Cite this page: Hill, M.A. (2026, November 20) Embryology Magnetic Resonance Imaging. Retrieved from https://embryology.med.unsw.edu.au/embryology/index.php/Talk:Magnetic_Resonance_Imaging

2015

2014

Fetal MRI: An approach to practice: A review

J Adv Res. 2014 Sep;5(5):507-23. doi: 10.1016/j.jare.2013.06.001. Epub 2013 Jun 11.

Saleem SN.

Abstract

MRI has been increasingly used for detailed visualization of the fetus in utero as well as pregnancy structures. Yet, the familiarity of radiologists and clinicians with fetal MRI is still limited. This article provides a practical approach to fetal MR imaging. Fetal MRI is an interactive scanning of the moving fetus owed to the use of fast sequences. Single-shot fast spin-echo (SSFSE) T2-weighted imaging is a standard sequence. T1-weighted sequences are primarily used to demonstrate fat, calcification and hemorrhage. Balanced steady-state free-precession (SSFP), are beneficial in demonstrating fetal structures as the heart and vessels. Diffusion weighted imaging (DWI), MR spectroscopy (MRS), and diffusion tensor imaging (DTI) have potential applications in fetal imaging. Knowing the developing fetal MR anatomy is essential to detect abnormalities. MR evaluation of the developing fetal brain should include recognition of the multilayered-appearance of the cerebral parenchyma, knowledge of the timing of sulci appearance, myelination and changes in ventricular size. With advanced gestation, fetal organs as lungs and kidneys show significant changes in volume and T2-signal. Through a systematic approach, the normal anatomy of the developing fetus is shown to contrast with a wide spectrum of fetal disorders. The abnormalities displayed are graded in severity from simple common lesions to more complex rare cases. Complete fetal MRI is fulfilled by careful evaluation of the placenta, umbilical cord and amniotic cavity. Accurate interpretation of fetal MRI can provide valuable information that helps prenatal counseling, facilitate management decisions, guide therapy, and support research studies. KEYWORDS: Anomalies; Fetal; MRI; Prenatal PMID 25685519

ref name=PMID25685519

<pubmed>25685519</pubmed>| J Adv Res.


Image source: The MRI images are reproduced with the permission of Prof Sahar Saleem for educational purposes only and cannot be reproduced electronically or in writing without permission. http://creativecommons.org/licenses/by-nc-nd/3.0/


2013

Magnetic resonance diffusion-weighted imaging: reproducibility of regional apparent diffusion coefficients for the normal fetal brain

Ultrasound Obstet Gynecol. 2013 Feb;41(2):190-7. doi: 10.1002/uog.11219. Epub 2013 Jan 3.

Boyer AC1, Gonçalves LF, Lee W, Shetty A, Holman A, Yeo L, Romero R.

Abstract

OBJECTIVE: To evaluate the reproducibility of regional apparent diffusion coefficient (ADC) measurements of the normal fetal brain in the second and third trimesters of pregnancy. METHODS: Fifty normal singleton fetuses from healthy pregnant women between 19 and 37 weeks' gestation were studied without sedation. Single-shot diffusion-weighted images of the fetal brain were obtained using a 1.5-Tesla magnetic resonance scanner and a six-channel body array coil. ADC maps were created using 0 and 1000 b-values along three orthogonal directions. Two examiners independently measured ADC values in the cerebellar hemispheres (CH), pons, thalamus, basal ganglia (BG), centrum semiovale (CSO), and frontal (FWM), parietal (PWM), temporal (TWM) and occipital (OWM) white matter. Correlation between ADC values and menstrual age was assessed by linear regression analysis. The bias and agreement of ADC measurements were determined using Bland-Altman plots. RESULTS: ADC values either remained constant (BG, FWM, PWM, TWM, OWM, CSO) or decreased (CH, pons, thalamus) with advancing menstrual age. Mean intraobserver bias for ADC measurements was not significantly different from zero. Small interobserver differences in mean ADC measurements (i.e. a small mean bias) were detected for CH (1.26 ± 0.20 vs 1.20 ± 0.18 μm(2) /ms, P = 0.006), PWM (1.37 ± 0.29 vs 1.33 ± 0.26 μm(2) /ms, P = 0.02) and CSO (1.36 ± 0.29 vs 1.33 ± 0.28 μm(2) /ms, P < 0.0001). Measurement agreement was acceptable. CONCLUSIONS: ADC measurements in normal unsedated fetuses in the second and third trimesters are reproducible except for small differences for PWM, CH and CSO between examiners. Copyright © 2013 ISUOG. Published by John Wiley & Sons, Ltd.

PMID 22744761


2012

Human birth observed in real-time open magnetic resonance imaging

Am J Obstet Gynecol. 2012 Jun;206(6):505.e1-6. Epub 2012 Jan 13.

Bamberg C, Rademacher G, Güttler F, Teichgräber U, Cremer M, Bührer C, Spies C, Hinkson L, Henrich W, Kalache KD, Dudenhausen JW. Source Department of Obstetrics, Charité University Hospital Berlin, Berlin, Germany.

Abstract

OBJECTIVE: Knowledge about the mechanism of labor is based on assumptions and radiographic studies performed decades ago. The goal of this study was to describe the relationship between the fetus and the pelvis as the fetus travels through the birth canal, using an open magnetic resonance imaging (MRI) scanner. STUDY DESIGN: The design of the study used a real-time MRI series during delivery of the fetal head. RESULTS: Delivery occurred by progressive head extension. However, extension was a very late movement that was observed when the occiput was in close contact with the inferior margin of the symphysis pubis, occurring simultaneously with gliding downward of the fetal head. CONCLUSION: This observational study shows, for the first time, that birth can be analyzed with real-time MRI. MRI technology allows assessment of maternal and fetal anatomy during labor and delivery. Copyright © 2012 Mosby, Inc. All rights reserved.

PMID 22425409

MRI: is there a role in obstetrics?

Clin Obstet Gynecol. 2012 Mar;55(1):352-66.

Hibbeln JF, Shors SM, Byrd SE. Source Department of Diagnostic Radiology and Nuclear Medicine, Rush University Medical Center, Chicago, Illinois 60612, USA. john_hibbeln@rush.edu

Abstract

Magnetic resonance imaging has a complementary role in obstetrical imaging to ultrasound (US). Although US has advantages as an initial imaging technique, there are significant numbers of patients who cannot be adequately evaluated for a variety of reasons including calvarial calcification, oligoanhydramnios, or simply obesity. MR can provide additional information that cannot be obtained by US and is invaluable in central nervous system anomaly evaluation, airway management, and planning for postnatal intervention. Newer techniques established in the postnatal population such as spectroscopy, diffusion-weighted imaging, and functional imaging have future applications in the fetus.

PMID 22343250

2011

Magnetic resonance imaging and gynecological devices

Contraception. 2011 Nov 29. [Epub ahead of print]

Correia L, Ramos AB, Machado AI, Rosa D, Marques C. Source Maternidade Dr. Alfredo da Costa, Lisbon, Portugal.

Abstract

BACKGROUND: Performing magnetic resonance imaging (MRI) on women with gynecological devices is a completely accepted practice. The goal of our review is to assess how safe it is to perform MRI on women using contraceptive implants or devices. STUDY DESIGN: Literature review, searching in PubMed-Medline/Ovid for the following keywords: magnetic resonance imaging, intrauterine devices, Implanon® and Essure ®. RESULTS: Though plastic devices do not represent a contraindication to the use of the technique, those including metallic components have been submitted to several tests, after which they were classified as MR Conditional (devices presenting no risks in MR-specific environments) by the Food and Drug Administration. Thus, the use of MRI can be safely advised to women with this type of device as long as the magnetic resonance equipment is ≤3.0 T. CONCLUSIONS: Presently, there is no scientific evidence that contraindicates performing MRI on women with any kind of gynecological device. Therefore, this procedure is safe as long as it is performed under previously tested conditions. Copyright © 2011 Elsevier Inc. All rights reserved.

PMID 22133659

Situs anomalies on prenatal MRI

Eur J Radiol. 2011 Jun 27. [Epub ahead of print]

Nemec SF, Brugger PC, Nemec U, Bettelheim D, Kasprian G, Amann G, Rimoin DL, Graham JM Jr, Prayer D. Source Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria; Medical Genetics Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, PACT Suite 400, Los Angeles, CA 90048, USA.

Abstract

OBJECTIVE: Situs anomalies refer to an abnormal organ arrangement, which may be associated with severe errors of development. Due regard being given to prenatal magnetic resonance imaging (MRI) as an adjunct to ultrasonography (US), this study sought to demonstrate the in utero visualization of situs anomalies on MRI, compared to US.

MATERIALS AND METHODS: This retrospective study included 12 fetuses with situs anomalies depicted on fetal MRI using prenatal US as a comparison modality. With an MRI standard protocol, the whole fetus was assessed for anomalies, with regard to the position and morphology of the following structures: heart; venous drainage and aorta; stomach and intestines; liver and gallbladder; and the presence and number of spleens.

RESULTS: Situs inversus totalis was found in 3/12 fetuses; situs inversus with levocardia in 1/12 fetuses; situs inversus abdominis in 2/12 fetuses; situs ambiguous with polysplenia in 3/12 fetuses, and with asplenia in 2/12 fetuses; and isolated dextrocardia in 1/12 fetuses. Congenital heart defects (CHDs), vascular anomalies, and intestinal malrotations were the most frequent associated malformations. In 5/12 cases, the US and MRI diagnoses were concordant. Compared to US, in 7/12 cases, additional MRI findings specified the situs anomaly, but CHDs were only partially visualized in six cases.

CONCLUSIONS: Our initial MRI results demonstrate the visualization of situs anomalies and associated malformations in utero, which may provide important information for perinatal management. Using a standard protocol, MRI may identify additional findings, compared to US, which confirm and specify the situs anomaly, but, with limited MRI visualization of fetal CHDs.

Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

PMID: 21715116 http://www.ncbi.nlm.nih.gov/pubmed/21715116


Abnormalities of the Upper Extremities on Fetal MRI

Ultrasound Obstet Gynecol. 2011 Jan 24. doi: 10.1002/uog.8949. [Epub ahead of print]

Nemec SF, Kasprian G, Brugger PC, Bettelheim D, Amann G, Nemec U, Rotmensch S, Graham JM Jr, Rimoin DL, Lachman RS, Prayer D. Source Department of Radiology, Division of Neuroradiology and Musculoskeletal Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria; Medical Genetics Institute, Cedars Sinai Medical Center, 8700 Beverly Boulevard, PACT Suite 400, Los Angeles, California 90048, USA. stefan.nemec@meduniwien.ac.at, stefan.nemec@cshs.org. Abstract OBJECTIVE: In view of the increasing use of fetal magnetic resonance imaging (MRI) as an adjunct to prenatal ultrasonography (US), we sought to demonstrate the visualization of upper extremity abnormalities and associated defects on MRI, with regard to fetal outcomes and compared to US.

METHODS: This retrospective study included 29 fetuses with upper extremity abnormalities that were positively depicted with fetal MRI and confirmed by postnatal assessment or autopsy. On a 1.5 Tesla unit, dedicated sequences were applied to image the extremities. CNS and extra-CNS anomalies were assessed to define extremity abnormalities as isolated or complex with associated defects. Fetal outcome was identified from medical records. The MRI and US findings were compared.

RESULTS: Isolated upper extremity abnormalities were found in 3/29 (10.3%) fetuses. Complex abnormalities were demonstrated in 26/29 (89.7%) fetuses, including postural extremity disorders (21/26) and structural extremity abnormalities (15/26). Associated defects involved: face (15/26); musculoskeletal system (14/26); thorax and cardio/pulmonary system (12/26); lower extremities (12/26); brain and skull (10/26); and abdomen (8/26). Of 29 cases, 18 (62.1%) pregnancies were delivered and 11 (37.9%) were terminated. MRI and US were compared in 27/29 cases: the diagnosis was concordant in 14/27 (51.9%) cases, and additional MRI findings were made in 13/27 (48.1%) cases.

CONCLUSIONS: Our results demonstrate that the visualization of upper extremity abnormalities on fetal MRI enables the differentiation between isolated and complex defects, which may be related to poor fetal prognosis. MRI mostly confirms the US diagnosis, but may provide additional findings in certain cases. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

PMID: 21308835 http://www.ncbi.nlm.nih.gov/pubmed/21308835

Relationship between fetal head station established using an open magnetic resonance imaging scanner and the "angle of progression" determined by transperineal ultrasound

Ultrasound Obstet Gynecol. 2011 Jan 24. doi: 10.1002/uog.8944. [Epub ahead of print]

Bamberg C, Scheuermann S, Slowinski T, Dückelmann A, Vogt M, Nguyen-Dobinsky T, Streitparth F, Teichgräber U, Henrich W, Dudenhausen J, Kalache K. Department of Obstetrics -Charité University Hospital - Campus Mitte, Berlin Germany.

Abstract

OBJECTIVES: We investigated the correlation between the angle of progression measured by transperineal ultrasound and fetal head station measured by open magnetic resonance imaging (MRI), the gold standard, in pregnant women at full term.

METHODS: Thirty-one pregnant women at full term with a fetus in the occipitoanterior position were enrolled. First, the distance between the leading part of the skull and the interspinal plane was obtained with an open MRI system with the patients in supine position. Then, immediately after the MRI, the angle of progression was obtained by transperineal ultrasound without changing the women's posture.

RESULTS: There was a significant correlation between the angle of progression determined by transperineal sonography and the distance between the presenting fetal part and the level of the maternal ischial spines (y = -0·51x + 60·8, r(2) = 0·38, p<0·001).

CONCLUSIONS: The present study demonstrated a predictable relationship between the angle of progression obtained by transperineal ultrasound and the traditional scale to quantify fetal head descent. Based on our results, station 0 would correspond to a 120° angle of progression. However, this correlation is based on statistical assumption only and has to be proven in future studies. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

PMID: 21308830 http://www.ncbi.nlm.nih.gov/pubmed/21308830

2010

Temperature elevation in the fetus from electromagnetic exposure during magnetic resonance imaging

Phys Med Biol. 2010 Apr 21;55(8):2411-26. Epub 2010 Apr 1.

Kikuchi S, Saito K, Takahashi M, Ito K.

Graduate School of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku, Chiba 263-8522, Japan. kikuchi@graduate.chiba-u.jp Abstract This study computationally assessed the temperature elevations due to electromagnetic wave energy deposition during magnetic resonance imaging in non-pregnant and pregnant woman models. We used a thermal model with thermoregulatory response of the human body for our calculations. We also considered the effect of blood temperature variation on body core temperature. In a thermal equilibrium state, the temperature elevations in the intrinsic tissues of the woman and fetal tissues were 0.85 and 0.61 degrees C, respectively, at a whole-body averaged specific absorption rate of 2.0 W kg(-1), which is the restriction value of the International Electrotechnical Commission for the normal operating mode. As predicted, these values are below the temperature elevation of 1.5 degrees C that is expected to be teratogenic. However, these values exceeded the recommended temperature elevation limit of 0.5 degrees C by the International Commission on Non-Ionizing Radiation Protection. We also assessed the irradiation time required for a temperature elevation of 0.5 degrees C at the aforementioned specific absorption rate. As a result, the calculated irradiation time was 40 min.

PMID: 20360633 http://www.ncbi.nlm.nih.gov/pubmed/20360633

http://iopscience.iop.org/0031-9155/55/8/018


Numerical study of RF exposure and the resulting temperature rise in the foetus during a magnetic resonance procedure

Phys Med Biol. 2010 Feb 21;55(4):913-30. Epub 2010 Jan 20.

Hand JW, Li Y, Hajnal JV.

Imaging Sciences Department, Imperial College London, London W12 0NN, UK. j.hand@imperial.ac.uk Abstract Numerical simulations of specific absorption rate (SAR) and temperature changes in a 26-week pregnant woman model within typical birdcage body coils as used in 1.5 T and 3 T MRI scanners are described. Spatial distributions of SAR and the resulting spatial and temporal changes in temperature are determined using a finite difference time domain method and a finite difference bio-heat transfer solver that accounts for discrete vessels. Heat transfer from foetus to placenta via the umbilical vein and arteries as well as that across the foetal skin/amniotic fluid/uterine wall boundaries is modelled. Results suggest that for procedures compliant with IEC normal mode conditions (maternal whole-body averaged SAR(MWB) < or = 2 W kg(-1) (continuous or time-averaged over 6 min)), whole foetal SAR, local foetal SAR(10 g) and average foetal temperature are within international safety limits. For continuous RF exposure at SAR(MWB) = 2 W kg(-1) over periods of 7.5 min or longer, a maximum local foetal temperature >38 degrees C may occur. However, assessment of the risk posed by such maximum temperatures predicted in a static model is difficult because of frequent foetal movement. Results also confirm that when SAR(MWB) = 2 W kg(-1), some local SAR(10g) values in the mother's trunk and extremities exceed recommended limits.

PMID: 20090188 http://www.ncbi.nlm.nih.gov/pubmed/20090188

Dealing with pregnancy in radiology: a thin line between science, social and regulatory aspects

JBR-BTR. 2009 Nov-Dec;92(6):271-9.

Buls N, Covens P, Nieboer K, Van Schuerbeek P, Devacht P, Eloot L, de Mey J.

Dienst Radiologie and Dienst Fysische controle, UZ Brussel, Brussels, Belgium. Abstract The participation of pregnant women in radiology can be an emotional experience. The word "radiation" understandably invokes fear and uncertainty. Irradiation of a foetus should be avoided whenever possible. However, radiological examinations of pregnant women are often justified and unintended exposures do occur. Also pregnant radiology staff may remain working in the department. Lack of knowledge about the effects of both ionising (X-rays) and non-ionising (MRI) radiation is responsible for anxiety of patients and workers. If foetal exposures occur, they must be quantitatively evaluated and the risk put into perspective. This paper is intended to inform radiology managers, radiologists, technologists and referring clinicians in their management with pregnant patients and co-workers. The paper describes conceptus doses for both patient and worker that are associated with radiology practice, reviews the risks and effects of in utero irradiation, and discusses current national policies, international guidelines and practical aspects.

PMID: 20166494 http://www.ncbi.nlm.nih.gov/pubmed/20166494

World-first at Charité: Birth in "open" MRI

Developmental atlas of the early first trimester human embryo

http://onlinelibrary.wiley.com/doi/10.1002/dvdy.22316/full


2004

MR imaging of fetal abnormalities

Tamsel S, Ozbek SS, Sener RN, Oztekin O, Demirpolat G. Comput Med Imaging Graph. 2004 Apr;28(3):141-9. PMID: 15081497

2000

Ultrafast MR imaging of the fetus

Kubik-Huch RA, Huisman TA, Wisser J, Gottstein-Aalame N, Debatin JF, Seifert B, Ladd ME, Stallmach T, Marincek B. AJR Am J Roentgenol. 2000 Jun;174(6):1599-606. PMID: 10845491

Mouse Brain Atlas MRI Database

Contacted Dr Cecilia Lo (cel36@pitt.edu) 16 August, 14 December 2010. Chien-fu Chang (chc160@pitt.edu) applications developer.

Registered 14 December 2010 see email for login information.