===New fetal weight estimation models using fractional limb volume=== | |||
Ultrasound Obstet Gynecol. 2009 Nov;34(5):556-65. | |||
Lee W, Balasubramaniam M, Deter RL, Yeo L, Hassan SS, Gotsch F, Kusanovic JP, Gonçalves LF, Romero R. | |||
Source | |||
Division of Fetal Imaging, Department of Obstetrics and Gynecology, Oakland University William Beaumont School of Medicine, Royal Oak, MI 48073-6769, USA. wlee@beaumont.edu | |||
Abstract | |||
OBJECTIVES: | |||
The main goal of this study was to determine the accuracy and precision of new fetal weight estimation models, based on fractional limb volume and conventional two-dimensional (2D) sonographic measurements during the second and third trimesters of pregnancy. | |||
METHODS: | |||
A prospective cross-sectional study of 271 fetuses was performed using three-dimensional ultrasonography to extract standard measurements-biparietal diameter (BPD), abdominal circumference (AC) and femoral diaphysis length (FDL)-plus fractional arm volume (AVol) and fractional thigh volume (TVol) within 4 days of delivery. Weighted multiple linear regression analysis was used to develop 'modified Hadlock' models and new models using transformed predictors that included soft tissue parameters for estimating birth weight. Estimated and observed birth weights were compared using mean percent difference (systematic weight estimation error) and the SD of the percent differences (random weight estimation error). The proportion of newborns with estimated birth weight within 5 or 10% of actual birth weight were compared using McNemar's test. | |||
RESULTS: | |||
Birth weights in the study group ranged from 235 to 5790 g, with equal proportions of male and female infants. Six new fetal weight estimation models were compared with the results for modified Hadlock models with sample-specific coefficients. All the new models were very accurate, with mean percent differences that were not significantly different from zero. Model 3 (which used the natural logarithms of BPD, AC and AVol) and Model 6 (which used the natural logarithms of BPD, AC and TVol) provided the most precise weight estimations (random error = 6.6% of actual birth weight) as compared with 8.5% for the best original Hadlock model and 7.6% for a modified Hadlock model using sample-specific coefficients. Model 5 (which used the natural logarithms of AC and TVol) classified an additional 9.1% and 8.3% of the fetuses within 5% and 10% of actual birth weight and Model 6 classified an additional 7.3% and 4.1% of infants within 5% and 10% of actual birth weight. | |||
CONCLUSION: | |||
The precision of fetal weight estimation can be improved by adding fractional limb volume measurements to conventional 2D biometry. New models that consider fractional limb volume may offer novel insight into the contribution of soft tissue development to weight estimation. | |||
Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd. | |||
PMID 19725080 | |||
Revision as of 11:08, 17 October 2011
| About Discussion Pages |
|---|
On this website the Discussion Tab or "talk pages" for a topic has been used for several purposes:
Glossary Links
Cite this page: Hill, M.A. (2026, November 18) Embryology Birth-Weight. Retrieved from https://embryology.med.unsw.edu.au/embryology/index.php/Talk:Birth-Weight |
2010
Birth-weight prediction by two- and three-dimensional ultrasound imaging
Ultrasound Obstet Gynecol. 2010 Apr;35(4):426-33.
Bennini JR, Marussi EF, Barini R, Faro C, Peralta CF. Source Department of Obstetrics and Gynecology, Center for Integral Assistance to Women's Health, State University of Campinas Medical School, Campinas, Brazil.
Abstract
OBJECTIVES: To compare the accuracies of birth-weight predicting models derived from two-dimensional (2D) ultrasound parameters and from total fetal thigh volumes measured by three-dimensional (3D) ultrasound imaging; and to compare the performances of these formulae with those of previously published equations.
METHODS: A total of 210 patients were evaluated to create a formula-generating group (n = 150) and a prospective-validation group (n = 60). Polynomial regression analysis was performed on the first group to generate one equation based on 2D ultrasound measurements, one based on fetal thigh volume measured by the multiplanar technique (ThiM) and one based on fetal thigh volume obtained by the Virtual Organ Computer-aided AnaLysis (VOCAL()) method (ThiV). Paired-samples t-tests with Bonferroni adjustments were used to compare the performances of these equations in the formula-finding and the prospective-validation groups. The same approach was used to compare the accuracies of the new 2D and 3D formulae with those of both original and modified 2D equations from previous publications, as well as the 3D model reported by Chang et al.
RESULTS: The formulae with the best fit for the prediction of birth weight were: estimated fetal weight (EFW) = - 562.824 + 11.962x AC x FDL + 0.009 x BPD(2)x AC(2) (where AC is abdominal circumference, FDL is femur diaphysis length and BPD is biparietal diameter), EFW = 1033.286 + 12.733 x ThiM, and EFW = 1025.383 + 12.775 x ThiV. For both the formula-generating and the prospective-validation groups, there were no significant differences between the accuracies of the new 2D and 3D models in the prediction of birth weight. When applied to our population, the performances of the modified and original versions of the previously published 2D equations and the performance of the original 3D formula reported by Chang et al. were all significantly worse than our models.
CONCLUSIONS: We believe that the greatest sources of discrepancy in estimation of birth weight are the phenotypic differences among patients used to create each of the formulae mentioned in this study. Our data reinforce the need for customized birth-weight prediction formulae, regardless of whether 2D or 3D measurements are employed.
Copyright 2009 ISUOG. Published by John Wiley & Sons, Ltd.
PMID 20069666
Estimate of birth weight using two- and three-dimensional ultrasonography
Rev Assoc Med Bras. 2010 Mar-Apr;56(2):204-8.
(Article in Portuguese)
Nardozza LM, Araújo Junior E, Vieira MF, Rolo LC, Moron AF. Source Departamento de Obstetrícia, Universidade Federal de São Paulo- Escola Paulista de Medicina - UNIFESP-EPM, São Paulo, SP. lunardozza@uol.com.br Abstract OBJECTIVE: Assess and compare accuracy of birth weight prediction using a combination of two-dimensional (abdominal circumference - AC and femur length - FL) and three-dimensional parameters (fetal arm -VolArm and thigh -VolTh volumes).
METHODS: A cross sectional study was carried out involving 78 singleton, live, euploid fetuses without structural malformations born within 48 hours after ultrasonography. VolArm and VolTh were obtained by three-dimensional ultrasound using the multiplanar mode at 5 mm intervals. AC and FL were measured by two-dimensional ultrasound. Linear and polynomial regressions were calculated to determine the best formula to predict birth weight using VolArm, VolTh , CA and FL. ANOVA was used to compare errors in birth weight prediction using this formula and those obtained using the Shepard and Hadlock formulae.
RESULTS: The best formula for prediction of birth weight was a simple linear regression (Weight = -1486.1 + 60.5AC + 140.57FL + 16.6VolArm + 4.8VolTh), R2= 0.932. The error (E), absolute error (AE), percent error (PE) and absolute percent error (APE) for this new formula were 0 g, 0.2%, 112.2 g and 3.7%. This new formula had smaller E, AE, PE and APE than the Shepard formula and smaller AE and APE than Hadlock s formula.
CONCLUSION: A formula using VolArm, VolTh, AC and FL was more accurate for prediction of birth weight than formulae using only two-dimensional parameters.
PMID 20498996
2009
New fetal weight estimation models using fractional limb volume
Ultrasound Obstet Gynecol. 2009 Nov;34(5):556-65.
Lee W, Balasubramaniam M, Deter RL, Yeo L, Hassan SS, Gotsch F, Kusanovic JP, Gonçalves LF, Romero R. Source Division of Fetal Imaging, Department of Obstetrics and Gynecology, Oakland University William Beaumont School of Medicine, Royal Oak, MI 48073-6769, USA. wlee@beaumont.edu Abstract OBJECTIVES: The main goal of this study was to determine the accuracy and precision of new fetal weight estimation models, based on fractional limb volume and conventional two-dimensional (2D) sonographic measurements during the second and third trimesters of pregnancy.
METHODS: A prospective cross-sectional study of 271 fetuses was performed using three-dimensional ultrasonography to extract standard measurements-biparietal diameter (BPD), abdominal circumference (AC) and femoral diaphysis length (FDL)-plus fractional arm volume (AVol) and fractional thigh volume (TVol) within 4 days of delivery. Weighted multiple linear regression analysis was used to develop 'modified Hadlock' models and new models using transformed predictors that included soft tissue parameters for estimating birth weight. Estimated and observed birth weights were compared using mean percent difference (systematic weight estimation error) and the SD of the percent differences (random weight estimation error). The proportion of newborns with estimated birth weight within 5 or 10% of actual birth weight were compared using McNemar's test.
RESULTS: Birth weights in the study group ranged from 235 to 5790 g, with equal proportions of male and female infants. Six new fetal weight estimation models were compared with the results for modified Hadlock models with sample-specific coefficients. All the new models were very accurate, with mean percent differences that were not significantly different from zero. Model 3 (which used the natural logarithms of BPD, AC and AVol) and Model 6 (which used the natural logarithms of BPD, AC and TVol) provided the most precise weight estimations (random error = 6.6% of actual birth weight) as compared with 8.5% for the best original Hadlock model and 7.6% for a modified Hadlock model using sample-specific coefficients. Model 5 (which used the natural logarithms of AC and TVol) classified an additional 9.1% and 8.3% of the fetuses within 5% and 10% of actual birth weight and Model 6 classified an additional 7.3% and 4.1% of infants within 5% and 10% of actual birth weight.
CONCLUSION: The precision of fetal weight estimation can be improved by adding fractional limb volume measurements to conventional 2D biometry. New models that consider fractional limb volume may offer novel insight into the contribution of soft tissue development to weight estimation.
Copyright (c) 2009 ISUOG. Published by John Wiley & Sons, Ltd.
PMID 19725080